The SNMP section allows the configuration of the SNMP MIB residing within the ADC. The MIB can then be queried by third-party software capable of communicating with devices equipped with SNMP.
SNMP Settings
Option
Description
SNMP v1 / V2C
Tick the checkbox to enable the V1/V2C MIB.
SNMP v1 conforms with RFC-1157. SNMP V2c conforms with RFC-1901-1908
SNMP v3
Tick the checkbox to enable the V3 MIB. RFC-3411-3418.
The username for v3 is admin.
Example:- snmpwalk -v3 -u admin -A jetnexus -l authNoPriv 192.168.1.11 1.3.6.1.4.1.38370
Community String
This is the read-only string set on the agent and used by the manager to retrieve the SNMP information. The default community string is jetnexus
PassPhrase
This is the password needed when SNMP v3 is enabled and must be at least 8 characters or more and contain letters Aa-Zz and numbers 0-9 only. The default passphrase is jetnexus